ORIGINAL ARTICLE
Year : 2016  |  Volume : 4  |  Issue : 2  |  Page : 59-63

Effect of blood contamination on the push-out bond strength of two endodontic biomaterials


1 Department of Endodontics, Faculty of dentistry, Shiraz University of Medical Sciences, Shiraz, Iran
2 Student, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran

Correspondence Address:
Dr. Fereshte Sobhnamayan
Department of Endodontics, Dental School of Medicine, Ghasrodasht Street, Ghomabad Avenue, Shiraz
Iran
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/2321-4619.180997

Rights and Permissions

Objectives: The aim of the present study was to compare the effect of blood contamination on the push-out bond strength of mineral trioxide aggregate (MTA) and calcium-enriched mixture (CEM) at different time intervals. Materials and Methods: One hundred and twenty dentin slices from single-rooted human teeth were sectioned and instrumented to achieve a diameter of 1.3 mm. The specimens were allocated into eight groups based on the materials used, the presence or absence of blood contamination, and the time. MTA and CEM were mixed and introduced into the lumens of dentin slices in groups 1–4 and 5–8, respectively. In blood-contaminated groups (1, 3, 5, and 7), the specimens were in direct contact with blood. The push-out test was performed in groups 1, 2, 5, and 6 after 3 days and in othergroups after 21 days. For the evaluation of failure modes, the samples were examined under a light microscope at × 40 magnifications. Data were analyzed by three-way analysis of variance (ANOVA). Results: The bond strength of MTA was higher than that of CEM, regardless of contamination and time (P < 0.05). For both materials, regardless of contamination, there was an increase in the bond strength from days 3to 21 (P < 0.05). Regardless of materials and time, blood contamination had no significant effect on the bond strength of materials (P > 0.05). Inspection of the samples revealed that the bond failure was predominantly of the mixed type in all groups. Conclusion: Blood contamination had no adverse effect on the bond strengths of both MTA and CEM; resistance of MTA to displacement was greater than that of CEM cement. However, the elapsed time, from 3 to 21 days, resulted in an increase in bond strength of both materials.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed1485    
    Printed84    
    Emailed0    
    PDF Downloaded416    
    Comments [Add]    

Recommend this journal