Home About us Editorial board Search Ahead of print Current issue Archives Submit article Instructions Subscribe Contacts Login 
Print this page Email this page Users Online: 265
ORIGINAL ARTICLE
Year : 2015  |  Volume : 3  |  Issue : 3  |  Page : 80-82

Influence of abutment-configuration on fracture strength of CAD/CAM-fabricated ceramic crowns


Department of Prosthetic Dentistry, University Medical Center, Mainz, Germany

Correspondence Address:
Dr. Michael Weyhrauch
Department of Prosthetic Dentistry, University Medical Center of the Johannes-Gutenberg University, Augustusplatz 2, 55131 Mainz
Germany
Login to access the Email id

Source of Support: None, Conflict of Interest: This study was self-founded by the authors and their institution. The authors want to thank the Vita Zahnfabrik GmbH and Co. KG for technical support by the fracture load tests.


DOI: 10.4103/2321-4619.168735

Rights and Permissions

Aims: This in vitro study assessed the fracture strength of computer-aided designing (CAD)/computer-aided manufacturing (CAM)-fabricated crowns on implant-abutments with different configurations. Subjects and Methods: Out of 30, 15 implant-abutments were shortened to 2 mm and a ball-headin metal-alloy was fixed on each abutment. Single crowns (Vita Mark II, Empress CAD, e. max CAD, Lava Ultimate, artBloc Temp Merz Dental, Telio CAD, and Vita CAD Temp) were designed. After cementation of the crowns using RelyX Unicem, a Zwick universal testing machine was used to aplicate occlusal force until the ceramic material was destroyed. Statistical Analysis Used: Statistical analysis were performed using analysis of variance (α =0.05) and Bonferroni correction. Results: This study has confirmed significant increases in fracture strength of crowns made of ceramic materials using the ball-head abutmentc on figuration. Conclusion: Within the limitations of this in vitro study, the following conclusions can be drawn: (1) The fracture strength of CAD/CAM-fabricated all-ceramic crowns could be increased using a rounded abutment up to 1.6 times. (2) The fracture strength of CAD/CAM-fabricated polymers could not be enhanced using a ball-head abutment. The increase of the fracture strength of all-ceramic crowns using the rounded abutment, could give reasons for the producers of implant abutments to improve their abutment design.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed1720    
    Printed39    
    Emailed0    
    PDF Downloaded221    
    Comments [Add]    

Recommend this journal